A home radon test is one of the quickest, lowest-cost ways to reduce a hidden lung cancer risk at home. This guide explains when to test, how to set it up correctly, what your pCi/L number means, and the proven fixes if levels are high. You will finish with a plan you can carry out this week.
Why radon matters in ordinary homes
Radon is an odorless radioactive gas that seeps into buildings from soil and rock. Long-term exposure increases lung cancer risk. It is identified as the second leading cause of lung cancer in the United States, and the risk is higher for people who smoke. Knowing your home’s level is the only way to address it, because you can’t see or smell it. (cdc.gov)
When to run a home radon test
Test if you have never tested, after major renovations that change airflow or foundation openings, before and after a real-estate transaction, every few years even if a past result was low, and after installing a mitigation system. If you use a basement or ground-floor room as a bedroom, office, or play area, place the device on that lowest lived-in level. These are standard recommendations in federal guidance. (semspub.epa.gov)
Short-term vs. long-term: which test to choose
Short-term tests measure radon for two to seven days, sometimes up to 90 days depending on device type. They are useful for a quick check or for real-estate timelines. Long-term tests run for 90 days or longer and give a better estimate of your home’s annual average, accounting for day-to-day and seasonal swings. A common approach is to start with a short-term test, then follow up with a long-term test if the first result is close to the action level or if you want higher confidence. (semspub.epa.gov)
How to place a home radon test correctly
Accurate setup matters more than brand. Use “closed-house” conditions for at least 12 hours before and during a short-term test: keep windows closed and only use doors for normal entry and exit. Place the device in a regularly occupied room on the lowest lived-in level, at least 20 inches above the floor, away from exterior walls, drafts, heat sources, humid spots like bathrooms, and kitchens. Do not place it in a crawlspace, sump pit, or laundry room. Follow device instructions carefully and mail or upload results promptly at the end of the test period. These placement and preparation steps come directly from federal testing guidance. (semspub.epa.gov)
Understanding pCi/L and the action level
Test results in the United States are typically reported in picocuries per liter (pCi/L). The federal action level is 4 pCi/L: homes at or above this level should be fixed. Because there is no known safe level of radon, guidance also recommends considering fixes for sustained results between 2 and 4 pCi/L. The average U.S. indoor level is about 1.3 pCi/L. (epa.gov)
What to do after your first result
- If your short-term result is 4 pCi/L or higher, take a follow-up test to confirm. If the first result was more than twice the action level, a second short-term test right away is advised to guide quick decisions.
- If your short-term result is between 2 and 4 pCi/L, follow up with a long-term test to estimate your annual average more accurately, then decide on mitigation.
- If your result is below 2 pCi/L, retest in a few years or after major changes to the home.
These next steps are outlined in national consumer guidance for homeowners. (semspub.epa.gov)
Mitigation that works—and why sealing alone is not enough
The most reliable fix for most houses with basements or slab-on-grade foundations is active sub-slab depressurization. A contractor runs PVC pipe from beneath the slab to the outside and uses a continuously operating inline fan to vent soil gases above the roofline. This changes pressure so radon does not enter the living space. Sealing cracks and openings helps the system work better, but sealing alone rarely lowers levels enough. Other designs exist for crawlspaces and different foundations, but the same principle applies: vent radon from below the home to the outdoors. (epa.gov)
How to find qualified help
Radon measurement and mitigation are specialized trades. Your state radon program can tell you if certification or licensing is required and provide contacts. Two national proficiency programs also maintain searchable lists of credentialed testers and mitigators. Hiring listed professionals ensures they follow standards of practice and use the right equipment for your foundation. (epa.gov)
Special cases: renters, multi-unit buildings, and wells
Renters can use an inexpensive short-term test in their unit and share results with the property owner. For multi-unit buildings, measurement protocols differ by building layout, and a qualified professional can advise which units to test. If your water comes from a private well and your air test shows elevated radon, ask your state program whether a water test is appropriate; treatment options exist for well water but the priority remains reducing radon in indoor air first. These points are reflected in federal materials for buyers, sellers, and homeowners. (nepis.epa.gov)
Common mistakes to avoid
- Placing the device in a kitchen, bathroom, laundry room, or near drafts and heat sources.
- Skipping closed-house conditions for a short-term test.
- Testing while a whole-house fan or window A/C is running; turn them off during a short-term test.
- Ignoring a borderline result; follow up to get the annual average.
- Delaying the mailing or upload of a completed test, which can affect results depending on device type.
These errors can skew readings; official homeowner guides emphasize proper placement and conditions to get a trustworthy number. (semspub.epa.gov)
After mitigation: verify and maintain
Every mitigation system should be followed by a post-installation test to confirm the reduction. Keep the fan running at all times, check the system’s indicator gauge periodically, and retest every couple of years or after significant changes to the building. Professional standards and consumer guides both call for ongoing verification, because radon levels can shift with seasons, soil moisture, and home modifications. (epa.gov)
Quick start: your next five steps
- Decide where you spend time on the lowest lived-in level; choose a room for testing.
- Get a short-term test kit or a continuous monitor from a reputable vendor or your state program.
- Set closed-house conditions, place the device correctly, and start the test.
- Read your pCi/L result. At 4 or higher, plan on mitigation; between 2 and 4, follow up with a long-term test.
- If mitigation is needed, contact your state radon program and search a national proficiency list for credentialed contractors. Retest after installation.
Following these steps transforms radon from an invisible worry into a solved problem with measurable results. (epa.gov)
Sources
CDC — Reducing Risk for Lung Cancer
US EPA — What is EPA’s Action Level for Radon and What Does it Mean?
US EPA — Consumer’s Guide to Radon Reduction: How to Fix Your Home (PDF)
US EPA — How to Find a Qualified Radon Service Provider
US EPA — Find a Radon Test Kit or Measurement and Mitigation Professional
National Cancer Institute — Radon and Cancer
Featured image: Wade Bush, Original AI-generated editorial image
More From This Category
View all Better Living →
A cooler evening starts before you switch on the air conditioner

Before you bin it: what a Repair Café can teach you about everyday objects

Efficient clothes drying starts before the dryer door opens

A good public park needs more than a beautiful view

Fans, blinds and timing: simple ways to reduce home cooling demand

Carbon monoxide alarm placement: where to put detectors before you turn on the heat
Other Articles You May Like

TikTok Creator Rewards eligibility — who qualifies, where, and which videos pay

FTC endorsement disclosure for creators: what to say and where it belongs

NAGPRA museum changes for visitors — what you’ll notice and how to be a better guest

Record the quiet: how room tone makes an interview edit feel natural

Bethlehem’s Church of the Nativity holds several architectural histories at once


